Abstract:Existing studies on the design of anchor-cable anti-slide piles lack systematic summaries,and some findings are merely theoretical analyses,which are hard to apply in practical engineering.Taking a practical engineering project as the background,the present study adopts the Plaxis numerical calculation method to systematically investigate key design parameters of anchor-cable anti-slide piles,including anti-slide pile spacing,layout and prestress of anchor cables,and anchorage depth of anti-slide piles.The results demonstrate that increasing anti-slide pile spacing can reduce the bending moment of the structure.Large-diameter piles with large spacing are recommended when construction conditions allow.Increasing the number of anchor-cable rows reduces the bending moment of anti-slide piles,whereas the magnitude of moment reduction gradually declines with the increase of anchor-cable rows.Therefore,the number of anchor-cable rows should be reasonably arranged with comprehensive consideration during design.Greater prestress of anchor-cables leads to a decrease in the positive bending moment and an increase in the negative bending moment of anti-slide piles.The design prestress of anchor cables should be determined so that the maximum negative bending moment is close to the maximum positive bending moment of anti-slide piles.The anchorage depth of anti-slide piles should be determined based on the distribution and development trend of plastic failure points to avoid excessively large or small anchorage depth.The research results can provide a reference for similar projects.